KYORITSU : Fork Current Tester 2300R
Check out the factory documentation here:
http://www.kew-ltd.co.jp/en/2300R
* True RMS reading is an essential feature for accurate measurement
* "Non Contact" voltage function indicates the presence of AC voltage by warning the user with an audible signal
* Set the DC current range to zero in one touch with the Zero Adjust function
* Data Hold (AC A / DC A only)
* Designed to international safety standard IEC61010-1 CAT.III 300V
KEW FORK 2300R can be used in crowded connection boxes, where cables are very short, and space is too limited to clamp cables using with a traditional clamp meter.
True RMS (Root Mean Square) Value Measurement
When load current is not affected by the distortion, both averaging value type and true RMS (root mean square) type clamp meters show the almost same value of about 10A with constant wave-form as the above display samples. However, when load current is affected by some distortions such as inverter, etc...,averaging value type clamp meter indicates 5.5A instead of 9.7A and true RMS type clamp meter indicates 7.9A instead of 9.7A with irregular wave-form. Accordingly, true RMS type clamp meter is recommendable for the measurement of the equipment with inverter control devices.
Due to the use of thyristors, inverters and other energy-saving controllers in recent electric wiring, current waveforms often include harmonic components and are distorted compared to sinusoidal waves (50/60Hz).
The Kyoritsu True RMS value tester is able to measure distorted waveforms using true RMS since waveforms are being internally calculated continuously. In contrast, when measurements are made with a averaging value tester, errors are generated in the measurement value because the tester cannot continuously track distorted waveforms.
(Compared to the true RMS value tester, measurement values for the averaging value generate more than 30% errors in some cases.)
Expedited Parcel (1-7 Business Days)
Expedited Parcel (5-12 Business Days)
13% HST for Nova Scotia, Newfoundland and New Brunswick
5% GST for rest Canadian Locations
* Postal Money Orders from the US are not accepted. (We accept International Postal Money Orders)
GUARANTEED AGAINST D.O.A. (DEAD ON ARRIVAL)
We accept your returns with 15% restocking charge for non defective return. This includes problem with compatibility, driver of software conflicts, improper installation etc.
Any returns made without following the above procedure may be REFUSED.
Please send email money transfer to 1627313617@iowa-industrial.com, send the answer to the same email address.
$15.00 CanadaPost Expedited Parcel
FREE scheduling, supersized images
Smart Services for Smart Sellers





Kyoritsu digital clamp meter /fork current tester japan